Product Specification
Brand | Shenyang Pusm Medical Device Co., Ltd. |
Condition | New |
Product Descriptions
Product infromation
1.Suitable for foot and hand surgery,
2.for a wide variety of joint operation of bone tissue cutting,
3.cutting rapidly, accurate location, bone edge smooth and tidy, low temperature rise,.
4.with a variety of specifications of the saw blade size :
13*15*0.6mm
73*8*0.6mm
73*4*0.6mm
45*12*0.4mm
45*8*0.4mm
45*4*0.4mm
saw blade can be customized.
5.better meet the needs of the clinical.
6.Input voltage : 110V-240V/50Hz
7.Output power : ≧120W
8.Battery capacity : 1600mA/h
9.Frequency : Approx.11000osc/min
10.Charging voltage : 7.2V
11.Sterilization : HTHP
12.Sterilizing temperature : 134℃-138℃
13.Noise : ≤70db
14.Port: Shenyang, China
15.MOQ: 1 set
16.Payment terms: T/T in advance
17. Delivery time: Within 10 days after received the payment
18.Packaging Details: One set packed in aluminum alloy box then put in one carton
19.Handpiece warranty is 12 months and lifetime maintenance. Battery warranty is 3 months.
Standard Configuration
1. One handpiece
2. Two batteries
3. One charger
4. One aseptic battery transfer ring
5. One operating manual
6. Four saw blades
6. One guarantee card
7. One certificate
Advantages:
1.Integrated Design
1.1.With this design, the bone drill and saw have excellent sealing.Therefore, when the device is sterilizted, the motor will be damaged less.
1.2.With this design, the decomposition of vibration is strong ,so that the noise is very small.
2.Ergonomic Design, Feel Comfortable
In the design, the weight of top and bottom are almost same, so it is avoid hand fatigue when using the product.
3.Large Battery Capacity
The battery capacity is larger than similar products in the market to make the power to satisfy the customers' needs.
4.Imported Motor
It can increase operation efficiency and precision.
Notes
1、Before the operation,the bone drill must be sterilized according to the sterilization.Battery and charger must not be sterilized.
2、Before the operation,the battery must be filled,and the filled battery must be cooled and then put into the handpiece.
3、After use,must to be cleaned,then remove the battery.And don’t put the battery and the handpiece together.Do not drop impact , to damage the battery.
4、Don’t put the battery in the place where the temperature is higher than 40℃
5、If there is abnormal phenomena during the operation,stop using it.
6、Prohibited in flammable, explosive materials nearby
7、If don’t use for long time, the battery should be regularly charged to ensure the battery life.