Product Specification
Condition | New |
Brand | Feiyuebio |
Warranty | YES |
Machine Type | Glass Coating Machine |
Product Descriptions
Bovine GH(Growth Hormone) ELISA Kit Basic Information
Product Name | Bovine GH(Growth Hormone) ELISA Kit |
Catalog NO. | FY-EB3812 |
Alias | GH ELISA Kit, GH N ELISA Kit, GH1 ELISA Kit, GHN ELISA Kit, Growth hormone ELISA Kit, growth hormone 1 ELISA Kit, hGH N ELISA Kit, Pituitary growth hormone ELISA Kit, Somatotropin ELISA Kit |
Size | 48T, 96T |
Storage | 2-8 ℃ for 6 months |
Sensitivity | <0.469ng/ml |
Species | Bovine |
UniProt ID | P01246 |
CV(%) | Intra-Assay: CV<8% |
Note | For Research Use Only |
Feiyue's Bovine GH(Growth Hormone) is an ELISA reagent for detection of GH antibody, plasma or cell with sensitivity, specificity and consistency.
Bovine GH(Growth Hormone) Introduction
GH is a peptide hormone that stimulates growth, cell reproduction, and cell regeneration in humans and other animals. It is thus important in human development. GH also stimulates production of IGF-1 and increases the concentration of glucose and free fatty acids. It is a type of mitogen which is specific only to the receptors on certain types of cells. GH is a 191-amino acid, single-chain polypeptide that is synthesized, stored and secreted by somatotropic cells within the lateral wings of the anterior pituitary gland. A recombinant form of hGH called somatropin (INN) is used as a prescription drug to treat children's growth disorders and adult growth hormone deficiency.
Bovine GH(Growth Hormone) ELISA Kit Test Method
This kit uses Competitive ELISA to detect the concentration of Bovine GH.
The microtiter plate provided in this kit has been pre-coated with target. During the reaction, target in the sample or standard competes with a fixed amount of target on the solid phase supporter for sites on the Biotinylated Detection Antibody specific to target. Excess conjugate and unbound sample or standard are washed from the plate, and HRP-Streptavidin (SABC) is added to each microplate well and incubated. Then TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm. The concentration of target in the samples is then determined by comparing the OD of the samples to the standard curve.
Reference:
- Ranabir S, Reetu K (January 2011). "Stress and hormones". Indian Journal of Endocrinology and Metabolism. 15 (1): 18–22. doi:10.4103/2230-8210.77573. PMC 3079864. PMID 21584161.
- Greenwood FC, Landon J (April 1966). "Growth hormone secretion in response to stress in man". Nature. 210 (5035): 540–1. doi:10.1038/210540a0. PMID 5960526. S2CID 1829264.