Product Specification
Brand | ANTAR TECHNOLOGY |
Condition | New |
Product Descriptions
Advantages
1.Semi-Dry Dental suction
2.Vacuum pump and separation system are centrely connect in the same long driving shaft
Technical Parameter
power | 220V/50HZ |
Input power | 1100W |
Maximum win pressure | 19kPa |
Vacuum degree | -18kPa |
Air Flow | 1200L/min |
N.W | 32kg |
G.W | 46kg |
Noise | 62dB |
Motor revolution | 2800r/min |
Product size | 48*32*70(cm) |
Packing size | 54*35*774(cm) |
- 1. Function Description
Its power system uses a wide-voltage dual-frequency motor in Grade IP55 protection (insulation grade: F) as its driver, to provide swirl-type circular suction with lower noise, higher pressure and larger flow.
Its filter system adopts the most advanced mechanical filter technology in terms of the current water treatment process, which can effectively remove the inhaled gel or other solid particulates.
Its effective two-level water-gas separator, with high bubble compatibility, could effectively prevent the fluid and blood in pipes being sucked into the pumping motor.
Configured with multiple layers of protection overload, and pressure relief safety devices, so that the device longer life.
**This device should be used with dental unit to remove droplets, spit and food residue in the patient’s mouth.
5.2 Installation conditions
Indoor: solid and flat ground without any shake.
Clean environment with good ventilation and without direct sunlight and harmful, corrosive gas.
It is recommended to provide a ventilator and some air outlets with a diameter of 38mm in the room where this device is installed, to discharge the exhaust gas and guarantee the fresh indoor air.
In addition, an underground sewage pipe with an inner diameter of 25mm should be equipped in the room to guarantee the removal of liquid waste from the suction system.
This device should be installed near the power socket with reliable grounding.
Keep this device far away from heat. No inflammable materials near it. Enough space should be provided near the suction system for ventilation.
No direct or indirect contact with damp objects is allowed in the installation site.
5.3 Requirements for normal operating environments
Ambient environment: +5℃ -- +40℃
Relative humidity: ≤70%
Atmosphere pressure: 700Hpa ~ 1060Hpa
5.4 Pipeline/signal line connection
A Connection of air intake pipe of the suction system
Please first connect the provided inlet pipe with the water inlet of the suction system:
Operate with your both hands: one holds the water inlet of the suction system and the other holds the inlet pipe and then rotate it inward.
Then, fasten it with the provided metal hose clamp
Connect the other end of the inlet pipe to the strong and weak exhaust pipes (or the preset underground main) on the dental chair
B Connection of exhaust pipe
Please connect one end of the provided exhaust pipe with the air outlet on the back of the suction system:
Hold one end of the exhaust pipe and then rotate it inward to connect to the air outlet.
Fasten it with the provided metal hose clamp.
Then, connect the other end of the exhaust pipe to the exhaust hole (or the preset exhaust manifold) on the wall.
Note: the exhaust pipe temperature will rise obviously when the suction system is working, so please use a metal pipe or heat resistant tube that could withstand an 80℃ high temperature as the exhaust extension tube.
C Connection of drainage pipe
Please connect one end of the provided drainage pipe with the water outlet on the back of the suction system:
Hold one end of the drainage pipe and then rotate it inward to connect to the water outlet.
Fasten it with the provided metal hose clamp.
Then, connect the other end of the drainage pipe to the sewer pipe.
Note: the drainage pipe in clinic cannot be installed higher than the water outlet.
D Connection of the suction system and the signal line of dental chair
The signal line used to connect this device to the dental chair is a multi-conductor line located near the power wire on the back of this device.
Connect the signal line with the heavy-current and light-current control system switch of the dental chair.
.
5.5 Use after connection
Power on, and turn on the green rocker switch at the lower right-hand corner on the device front, the power indicator light and the monitor will be on and the suction system enters a standby mode.
After confirming the signal switch on the back of the suction system
remove the strong or weak suction pipe on the dental chair and then the suction machine begins to work